{"id":1066,"date":"2024-05-10T16:25:36","date_gmt":"2024-05-10T21:25:36","guid":{"rendered":"https:\/\/blog.hilltech.com\/?p=1066"},"modified":"2024-05-10T16:25:37","modified_gmt":"2024-05-10T21:25:37","slug":"rc-snubber-transformer-protection-circuit-components","status":"publish","type":"post","link":"https:\/\/blog.hilltech.com\/?p=1066","title":{"rendered":"RC Snubber &#8211; Transformer Protection Circuit Components"},"content":{"rendered":"\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"730\" height=\"458\" src=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/05\/mv-snubber-cirucit-diagram_adjustments.jpg\" alt=\"Circuit Diagram RC Snubber per Phase\" class=\"wp-image-1092\" style=\"width:670px;height:auto\" srcset=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/05\/mv-snubber-cirucit-diagram_adjustments.jpg 730w, https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/05\/mv-snubber-cirucit-diagram_adjustments-300x188.jpg 300w\" sizes=\"auto, (max-width: 730px) 100vw, 730px\" \/><\/figure>\n\n\n\n<p>Resistor-Capacitor (RC) transformer protection snubber circuits safeguard medium voltage distribution transformers against transient overvoltages, which minimizes failures. RC snubber circuits are crucial for the protection of dry-type distribution transformers, especially when close-coupled to vacuum switching devices.<\/p>\n\n\n\n<p>These RC networks, consisting of RC configurations, are installed on the high voltage windings of transformers to mitigate transient overvoltages and dv\/dt events. They are primarily employed in three-phase distribution transformers.<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-medium-font-size\" id=\"Medium_Voltage_RC_Snubbers_counteract_damage_from_events_such_as:\" style=\"font-style:normal;font-weight:600\">Medium Voltage RC Snubbers counteract <strong>damage <\/strong>from events such as:<\/h2>\n\n\n\n<ol class=\"wp-block-list\" start=\"1\">\n<li>Switching on an unloaded or lightly loaded transformer.<\/li>\n\n\n\n<li>Transient recovery voltages (TRV) during transformer de-energization.<\/li>\n\n\n\n<li>Current chopping (CC).<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading has-medium-font-size\" style=\"font-style:normal;font-weight:600\">The snubber circuit comprises three fundamental medium voltage components per phase:<\/h2>\n\n\n\n<ol class=\"wp-block-list\" start=\"1\">\n<li>Damping resistors<\/li>\n\n\n\n<li>Surge capacitors<\/li>\n\n\n\n<li>Fuses<\/li>\n<\/ol>\n\n\n\n<p>Hill Tech can assist you with both your fuses and damping resistor requirements for RC snubber circuits.<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-medium-font-size\" style=\"font-style:normal;font-weight:600\">RC Snubber Circuit Components from Hill Tech<\/h2>\n\n\n\n<p><strong>DAMPING RESISTORS:<\/strong> These non-inductive tubular power resistors, constructed of either <a href=\"https:\/\/www.hilltech.com\/pdf\/Resistors\/rod-tubes-resistors.pdf\">carbon ceramic<\/a> or <a href=\"https:\/\/www.hilltech.com\/pdf\/Resistors\/silicon-glass-tube-resistors.pdf\">silicon glass<\/a>, are inherently non-inductive and can handle large surge energies with high continuous power ratings. They feature an anti-track coating and sufficient length, making them suitable for medium voltage applications.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/04\/rod-tube-high-surge-energy-non-inductive-ceramic-carbon-resistors.png\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/04\/rod-tube-high-surge-energy-non-inductive-ceramic-carbon-resistors.png\" alt=\"Rod and Tube Carbon Ceramic Resistors\" class=\"wp-image-1072\" style=\"width:300px;height:auto\" srcset=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/04\/rod-tube-high-surge-energy-non-inductive-ceramic-carbon-resistors.png 600w, https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/04\/rod-tube-high-surge-energy-non-inductive-ceramic-carbon-resistors-300x300.png 300w, https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/04\/rod-tube-high-surge-energy-non-inductive-ceramic-carbon-resistors-150x150.png 150w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/a><figcaption class=\"wp-element-caption\">Rod &amp; Tube Carbon Ceramic Resistors<\/figcaption><\/figure><\/div>\n\n\n<p>Depending on the surge energy and continuous power rating required by the resistor two different technologies should be considered either silicon glass resistor or carbon ceramic resistor type. Silicon-Glass Tube Resistors are rated up to 330kJ at 1000W and 30kV, whereas carbon ceramic tube resistors are rated up to 119kJ at 225W and 120kV. &nbsp;Contact Hill Tech with those requirements for the best technical solutions.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/04\/four-ceramic-composite-resistor-tubes.png\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/04\/four-ceramic-composite-resistor-tubes.png\" alt=\"Silicon Glass Tube Resistors\" class=\"wp-image-1073\" style=\"width:309px;height:auto\" srcset=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/04\/four-ceramic-composite-resistor-tubes.png 600w, https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/04\/four-ceramic-composite-resistor-tubes-300x300.png 300w, https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/04\/four-ceramic-composite-resistor-tubes-150x150.png 150w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/a><figcaption class=\"wp-element-caption\">Silicon Glass Tube Resistors<\/figcaption><\/figure><\/div>\n\n\n<p>Various mounting end-caps and clips are available for mounting these resistors.<\/p>\n\n\n\n<p><strong>FUSES:<\/strong> Fuses play a crucial role in preventing the destruction of the snubber circuit. If the fuses fail to operate, the resistors effectively act as fuses, resulting in the loss of protection provided by the snubber circuit.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft size-full is-resized\"><a href=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/04\/DSC6723_post.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/04\/DSC6723_post.jpg\" alt=\"High Voltage Fuse\" class=\"wp-image-1074\" style=\"width:247px;height:auto\" srcset=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/04\/DSC6723_post.jpg 1000w, https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/04\/DSC6723_post-300x300.jpg 300w, https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/04\/DSC6723_post-150x150.jpg 150w, https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/04\/DSC6723_post-768x768.jpg 768w, https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/04\/DSC6723_post-600x600.jpg 600w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/a><figcaption class=\"wp-element-caption\">High Voltage Fuse<\/figcaption><\/figure><\/div>\n\n\n<p>High-speed, current-limiting fuses, such as the new <a href=\"https:\/\/www.hilltech.com\/pdf\/fuses\/hhc-high-voltage-capacitor-fuses.pdf\">HHA-BC series<\/a>, are specifically designed for optimal performance in capacitor circuits. They are suitable for indoor and outdoor usage in the North American market. The voltage rating of the HHA-BC capacitor fuse matches or exceeds the maximum open circuit voltage of the system, ensuring effective operation during fault conditions.<\/p>\n\n\n\n<p>The HHA-BC capacitor fuse is available in various voltage ratings, including 4.8kV, 5.5kV, 7.2kV, 8.3kV, 15.5kV, and 23kV. We offer different mounting styles, such as threaded\/tapped ends (1\/2\u201d UNC or M16) and L-Bracket configurations with a 50N striker. The fuses equipped with a 50N striker offer visual fault detection through a bright red-colored striker and can also activate a microswitch assembly for remote monitoring.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright size-full is-resized\"><a href=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/04\/DSC6726_post.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/04\/DSC6726_post.jpg\" alt=\"High Voltage Fuse\" class=\"wp-image-1075\" style=\"width:234px;height:auto\" srcset=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/04\/DSC6726_post.jpg 1000w, https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/04\/DSC6726_post-300x300.jpg 300w, https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/04\/DSC6726_post-150x150.jpg 150w, https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/04\/DSC6726_post-768x768.jpg 768w, https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/04\/DSC6726_post-600x600.jpg 600w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/a><figcaption class=\"wp-element-caption\">High Voltage Fuse<\/figcaption><\/figure><\/div>\n\n\n<p>It&#8217;s worth noting that all new capacitor fuses equipped with 50N strikers feature a thermal limiter mechanism. This mechanism triggers the striker under overload conditions when the internal temperature of the fuse exceeds specified levels, enhancing safety and reliability.<\/p>\n\n\n\n<p>Hill Tech is pleased to support your component needs for RC transformer protection snubber circuits.<\/p>\n\n\n\n<p>If you would like to check out a variety of products that we handle that could suit your needs, please check out our website at <a href=\"https:\/\/hill-tech.com\/\">https:\/\/hill-tech.com\/<\/a>, or contact us at 847-255-4400, fax us at (847) 255-0192, or email us at <a href=\"mailto:sales@hilltech.com\">sales@hilltech.com<\/a>.<\/p>\n\n\n\n<h6 class=\"wp-block-heading has-text-align-center\">Hill Technical Sales provides expert design and implementation of quality components for Electrical Power Conversion &amp; Distribution, Thermal Management, UV Curing, and High-Speed Industrial Imaging for more information:<\/h6>\n\n\n\n<P class=MsoNormal style=\"MARGIN: 0in 0in 8pt; LINE-HEIGHT: 115%; TEXT-ALIGN: center\"><FONT face=Verdana><STRONG>Connect with us:<\/STRONG><\/FONT>&nbsp;&nbsp;&nbsp; <A href=\"https:\/\/www.linkedin.com\/company\/hill-technical-sales-corp\/\"><IMG src=\"https:\/\/www.hilltech.com\/images\/social\/LI-In-Bug-No-TM-25x25.png\" width=25 height=25><\/A>&nbsp;&nbsp;&nbsp;<A href=\"https:\/\/www.youtube.com\/channel\/UCaN0pZ-67dST23x-o8PMi5g\"><IMG src=\"https:\/\/www.hilltech.com\/images\/social\/youtube_social_squircle_red.png\" width=25 height=25><\/A>&nbsp;&nbsp;&nbsp; <A href=\"https:\/\/www.instagram.com\/hill_tech_sales\/\"><IMG src=\"https:\/\/www.hilltech.com\/images\/social\/Instagram_Glyph_Gradient.png\" width=25 height=25><\/A> &nbsp;&nbsp;&nbsp;<A href=\"https:\/\/blog.hilltech.com\"><IMG src=\"https:\/\/www.hilltech.com\/images\/social\/blog-h-icon.png\" width=25 height=25><\/A><\/P>\n","protected":false},"excerpt":{"rendered":"<p>Resistor-Capacitor (RC) transformer protection snubber circuits safeguard medium voltage distribution transformers against transient overvoltages, which minimizes failures. RC snubber circuits are crucial for the protection of dry-type distribution transformers, especially when close-coupled to vacuum switching devices. These RC networks, consisting &hellip; <a href=\"https:\/\/blog.hilltech.com\/?p=1066\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":9,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[165,180],"tags":[131,343,344,337,340,339,342,336,346,345],"class_list":["post-1066","post","type-post","status-publish","format-standard","hentry","category-fuse","category-learning_center_hill_tech_sales","tag-capacitor","tag-carbon-ceramic","tag-ceramic","tag-circuit","tag-damping-resistors","tag-fuses","tag-hha-bc-capacitor-fuse","tag-rc-transformer","tag-silicon","tag-silicon-glass"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>RC Snubber - Transformer Protection Circuit Components -<\/title>\n<meta name=\"description\" content=\"Hill Technical Sales offers fuses and damping resistors, key components for Resistor-Capacitor (RC) snubber transformer protection circuits.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.hilltech.com\/?p=1066\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"RC Snubber - Transformer Protection Circuit Components -\" \/>\n<meta property=\"og:description\" content=\"Hill Technical Sales offers fuses and damping resistors, key components for Resistor-Capacitor (RC) snubber transformer protection circuits.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.hilltech.com\/?p=1066\" \/>\n<meta property=\"og:site_name\" content=\"Hill Technical Sales Blog\" \/>\n<meta property=\"article:published_time\" content=\"2024-05-10T21:25:36+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-05-10T21:25:37+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/05\/mv-snubber-cirucit-diagram_adjustments.jpg\" \/>\n<meta name=\"author\" content=\"Kimberly Underwood\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Kimberly Underwood\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.hilltech.com\/?p=1066#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.hilltech.com\/?p=1066\"},\"author\":{\"name\":\"Kimberly Underwood\",\"@id\":\"https:\/\/blog.hilltech.com\/#\/schema\/person\/793be566354dde7ea8b69f84f49b2b34\"},\"headline\":\"RC Snubber &#8211; Transformer Protection Circuit Components\",\"datePublished\":\"2024-05-10T21:25:36+00:00\",\"dateModified\":\"2024-05-10T21:25:37+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.hilltech.com\/?p=1066\"},\"wordCount\":580,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/blog.hilltech.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/blog.hilltech.com\/?p=1066#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/05\/mv-snubber-cirucit-diagram_adjustments.jpg\",\"keywords\":[\"capacitor\",\"carbon ceramic\",\"ceramic\",\"circuit\",\"damping resistors\",\"fuses\",\"HHA-BC capacitor fuse\",\"RC transformer\",\"silicon\",\"silicon glass\"],\"articleSection\":[\"Fuse\",\"Learning Center\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/blog.hilltech.com\/?p=1066#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.hilltech.com\/?p=1066\",\"url\":\"https:\/\/blog.hilltech.com\/?p=1066\",\"name\":\"RC Snubber - Transformer Protection Circuit Components -\",\"isPartOf\":{\"@id\":\"https:\/\/blog.hilltech.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.hilltech.com\/?p=1066#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.hilltech.com\/?p=1066#primaryimage\"},\"thumbnailUrl\":\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/05\/mv-snubber-cirucit-diagram_adjustments.jpg\",\"datePublished\":\"2024-05-10T21:25:36+00:00\",\"dateModified\":\"2024-05-10T21:25:37+00:00\",\"description\":\"Hill Technical Sales offers fuses and damping resistors, key components for Resistor-Capacitor (RC) snubber transformer protection circuits.\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.hilltech.com\/?p=1066#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.hilltech.com\/?p=1066\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/blog.hilltech.com\/?p=1066#primaryimage\",\"url\":\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/05\/mv-snubber-cirucit-diagram_adjustments.jpg\",\"contentUrl\":\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/05\/mv-snubber-cirucit-diagram_adjustments.jpg\",\"width\":730,\"height\":458},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.hilltech.com\/?p=1066#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/blog.hilltech.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"RC Snubber &#8211; Transformer Protection Circuit Components\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.hilltech.com\/#website\",\"url\":\"https:\/\/blog.hilltech.com\/\",\"name\":\"Hill Technical Sales Blog\",\"description\":\"Your source for all your Power, Thermal Management and Imaging needs\",\"publisher\":{\"@id\":\"https:\/\/blog.hilltech.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.hilltech.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/blog.hilltech.com\/#organization\",\"name\":\"Hill Sales Corp\",\"alternateName\":\"Hill Technical Sales\",\"url\":\"https:\/\/blog.hilltech.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/blog.hilltech.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2016\/10\/Site-Icon-Hill-Tech-2.jpg\",\"contentUrl\":\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2016\/10\/Site-Icon-Hill-Tech-2.jpg\",\"width\":512,\"height\":512,\"caption\":\"Hill Sales Corp\"},\"image\":{\"@id\":\"https:\/\/blog.hilltech.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.linkedin.com\/company\/hill-technical-sales-corp\",\"https:\/\/www.youtube.com\/@HillTechnicalSales\",\"https:\/\/www.instagram.com\/hill_tech_sales\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/blog.hilltech.com\/#\/schema\/person\/793be566354dde7ea8b69f84f49b2b34\",\"name\":\"Kimberly Underwood\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/blog.hilltech.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/1787b6868f3935ae75a29505921eb056?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/1787b6868f3935ae75a29505921eb056?s=96&d=mm&r=g\",\"caption\":\"Kimberly Underwood\"},\"sameAs\":[\"http:\/\/www.hilltech.com\"],\"url\":\"https:\/\/blog.hilltech.com\/?author=9\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"RC Snubber - Transformer Protection Circuit Components -","description":"Hill Technical Sales offers fuses and damping resistors, key components for Resistor-Capacitor (RC) snubber transformer protection circuits.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.hilltech.com\/?p=1066","og_locale":"en_US","og_type":"article","og_title":"RC Snubber - Transformer Protection Circuit Components -","og_description":"Hill Technical Sales offers fuses and damping resistors, key components for Resistor-Capacitor (RC) snubber transformer protection circuits.","og_url":"https:\/\/blog.hilltech.com\/?p=1066","og_site_name":"Hill Technical Sales Blog","article_published_time":"2024-05-10T21:25:36+00:00","article_modified_time":"2024-05-10T21:25:37+00:00","og_image":[{"url":"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/05\/mv-snubber-cirucit-diagram_adjustments.jpg","type":"","width":"","height":""}],"author":"Kimberly Underwood","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Kimberly Underwood","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.hilltech.com\/?p=1066#article","isPartOf":{"@id":"https:\/\/blog.hilltech.com\/?p=1066"},"author":{"name":"Kimberly Underwood","@id":"https:\/\/blog.hilltech.com\/#\/schema\/person\/793be566354dde7ea8b69f84f49b2b34"},"headline":"RC Snubber &#8211; Transformer Protection Circuit Components","datePublished":"2024-05-10T21:25:36+00:00","dateModified":"2024-05-10T21:25:37+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.hilltech.com\/?p=1066"},"wordCount":580,"commentCount":0,"publisher":{"@id":"https:\/\/blog.hilltech.com\/#organization"},"image":{"@id":"https:\/\/blog.hilltech.com\/?p=1066#primaryimage"},"thumbnailUrl":"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/05\/mv-snubber-cirucit-diagram_adjustments.jpg","keywords":["capacitor","carbon ceramic","ceramic","circuit","damping resistors","fuses","HHA-BC capacitor fuse","RC transformer","silicon","silicon glass"],"articleSection":["Fuse","Learning Center"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/blog.hilltech.com\/?p=1066#respond"]}]},{"@type":"WebPage","@id":"https:\/\/blog.hilltech.com\/?p=1066","url":"https:\/\/blog.hilltech.com\/?p=1066","name":"RC Snubber - Transformer Protection Circuit Components -","isPartOf":{"@id":"https:\/\/blog.hilltech.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.hilltech.com\/?p=1066#primaryimage"},"image":{"@id":"https:\/\/blog.hilltech.com\/?p=1066#primaryimage"},"thumbnailUrl":"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/05\/mv-snubber-cirucit-diagram_adjustments.jpg","datePublished":"2024-05-10T21:25:36+00:00","dateModified":"2024-05-10T21:25:37+00:00","description":"Hill Technical Sales offers fuses and damping resistors, key components for Resistor-Capacitor (RC) snubber transformer protection circuits.","breadcrumb":{"@id":"https:\/\/blog.hilltech.com\/?p=1066#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.hilltech.com\/?p=1066"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.hilltech.com\/?p=1066#primaryimage","url":"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/05\/mv-snubber-cirucit-diagram_adjustments.jpg","contentUrl":"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2024\/05\/mv-snubber-cirucit-diagram_adjustments.jpg","width":730,"height":458},{"@type":"BreadcrumbList","@id":"https:\/\/blog.hilltech.com\/?p=1066#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.hilltech.com\/"},{"@type":"ListItem","position":2,"name":"RC Snubber &#8211; Transformer Protection Circuit Components"}]},{"@type":"WebSite","@id":"https:\/\/blog.hilltech.com\/#website","url":"https:\/\/blog.hilltech.com\/","name":"Hill Technical Sales Blog","description":"Your source for all your Power, Thermal Management and Imaging needs","publisher":{"@id":"https:\/\/blog.hilltech.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.hilltech.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/blog.hilltech.com\/#organization","name":"Hill Sales Corp","alternateName":"Hill Technical Sales","url":"https:\/\/blog.hilltech.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.hilltech.com\/#\/schema\/logo\/image\/","url":"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2016\/10\/Site-Icon-Hill-Tech-2.jpg","contentUrl":"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2016\/10\/Site-Icon-Hill-Tech-2.jpg","width":512,"height":512,"caption":"Hill Sales Corp"},"image":{"@id":"https:\/\/blog.hilltech.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/hill-technical-sales-corp","https:\/\/www.youtube.com\/@HillTechnicalSales","https:\/\/www.instagram.com\/hill_tech_sales\/"]},{"@type":"Person","@id":"https:\/\/blog.hilltech.com\/#\/schema\/person\/793be566354dde7ea8b69f84f49b2b34","name":"Kimberly Underwood","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.hilltech.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/1787b6868f3935ae75a29505921eb056?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/1787b6868f3935ae75a29505921eb056?s=96&d=mm&r=g","caption":"Kimberly Underwood"},"sameAs":["http:\/\/www.hilltech.com"],"url":"https:\/\/blog.hilltech.com\/?author=9"}]}},"_links":{"self":[{"href":"https:\/\/blog.hilltech.com\/index.php?rest_route=\/wp\/v2\/posts\/1066","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.hilltech.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.hilltech.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.hilltech.com\/index.php?rest_route=\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.hilltech.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1066"}],"version-history":[{"count":21,"href":"https:\/\/blog.hilltech.com\/index.php?rest_route=\/wp\/v2\/posts\/1066\/revisions"}],"predecessor-version":[{"id":1101,"href":"https:\/\/blog.hilltech.com\/index.php?rest_route=\/wp\/v2\/posts\/1066\/revisions\/1101"}],"wp:attachment":[{"href":"https:\/\/blog.hilltech.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1066"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.hilltech.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=1066"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.hilltech.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=1066"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}