{"id":186,"date":"2013-06-26T15:51:55","date_gmt":"2013-06-26T20:51:55","guid":{"rendered":"http:\/\/blog.hilltech.com\/?p=186"},"modified":"2022-04-06T22:17:29","modified_gmt":"2022-04-07T03:17:29","slug":"reduce-the-size-of-switchgear-designs-and-increase-safety","status":"publish","type":"post","link":"https:\/\/blog.hilltech.com\/?p=186","title":{"rendered":"Reduce the size of switchgear designs and increase safety"},"content":{"rendered":"<p><strong>ARLINGTON HEIGHTS, ILLINOIS, USA<\/strong>, Monday, June 24, 2013: Hill Tech Sales, a leader in Components for Electrical Power Conversion today posted information on using true Full-range fuses to reduce the\u00a0size of switchgear.<\/p>\n<p>In the past, Full-range fuses used an inappropriate element design where they \u201cage\u201d prematurely because they operate in the fast overcurrent range. This ageing is the changing element\u2019s characteristics because of the increased power loss during operation.<\/p>\n<p>Correctly designed <a title=\"Full-range fuse data sheet\" href=\"ftp:\/\/hilltech@hilltech.com\/www\/pdf\/fuses\/SIBA%20H00603_0.pdf\" target=\"_blank\" rel=\"noopener\">Full-range fuses <\/a>will interrupt any value of current from short-circuit to overload interruption. They have all the characteristics of back-up fuses plus the further ability for protection in the overload range. Distribution transformer circuits should use Full-range fuses where there may not be protection on the secondary side of the transformer, and the primary fuse is needed to clear a secondary system fault.<\/p>\n<p><strong>Full-Range fuse other\u00a0construction concept<\/strong><\/p>\n<div id=\"attachment_191\" style=\"width: 322px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2013\/06\/Back-up-construction.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-191\" class=\" wp-image-191\" title=\"Back-up fuse construction\" src=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2013\/06\/Back-up-construction-300x225.jpg\" alt=\"Back-up &amp; General Purpose fuse\" width=\"312\" height=\"217\" \/><\/a><p id=\"caption-attachment-191\" class=\"wp-caption-text\">Typical construction for Back-up &amp; General Purpose fuses<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Our Full-range<a title=\"Fuses on Hill Tech site\" href=\"http:\/\/www.hilltech.com\/products\/power_components\/p_fuses_hi.html#High\" target=\"_blank\" rel=\"noopener\"> fuses <\/a>are designed using a two zone design concept; each zone has a different element design which lowers power losses and temperature rise leading to reliable operation in the overload range.<\/p>\n<p><strong>Full-Range fuse NEW concept<\/strong><\/p>\n<div id=\"attachment_188\" style=\"width: 352px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2013\/06\/full_range_fuse-cut-away-V1.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-188\" class=\" wp-image-188\" title=\"Full-range fuse dual zone method \" src=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2013\/06\/full_range_fuse-cut-away-V1-300x240.jpg\" alt=\"A true Full-range fuse uses a dual zone construction\" width=\"342\" height=\"244\" \/><\/a><p id=\"caption-attachment-188\" class=\"wp-caption-text\">Other Full-range fuse do not use a dual zone construction<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong>New design concept for Full-range fuses:<\/strong><br \/>\nTwo Zone concept, back-up zone, overload zone (Thermal Zone)<br \/>\nSpecial melting element material for parallel melting element design<\/p>\n<p><strong>Back-up zone<\/strong><br \/>\nBack-up zone consists of upto 15 individual silver melting elements wound onto a star-shaped carrier imbedded in quartz sand.<\/p>\n<p><strong>Overload zone (Thermal Zone)<\/strong><br \/>\nThe elements in this zone are notched, which reduces the element cross section generating power loss and\u00a0creating heat. In order to minimize the effects of this heat, two things are done. First, the heat is confined to a thermal separated from other parts of the fuse by a thermal barrier. Secondly, the melting elements are made of a special alloy differentiating it from silver (melting point 960\u00b0C) which is typically used.<\/p>\n<div id=\"attachment_187\" style=\"width: 310px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2013\/06\/Full_range_construction.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-187\" class=\"size-medium wp-image-187\" title=\"Full-range fuse dual zone construction\" src=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2013\/06\/Full_range_construction-300x146.jpg\" alt=\"Note the two different windings in this Full-range fuse\" width=\"300\" height=\"146\" srcset=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2013\/06\/Full_range_construction-300x146.jpg 300w, https:\/\/blog.hilltech.com\/wp-content\/uploads\/2013\/06\/Full_range_construction.jpg 764w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-187\" class=\"wp-caption-text\">Full-range fuse dual zone method<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Melting element materials has three important properties:<\/strong><\/p>\n<ol>\n<li>Low melting point ~ 600\u00b0C.<\/li>\n<li>Enhanced heat absorption by the decay of metal-oxide components in the arcing process. Metal oxides are created by internal oxidation of the alloy just before reaching the melting temperature.<\/li>\n<li>Increased recovery voltage. The AC voltage arc is immediately absorbed after current zero making re-ignition very high. These fault arcs are extinguished much faster when made of this alloy as compared to elements of pure silver.<\/li>\n<\/ol>\n<p>The two zones are placed in series for good short-circuit and overload protection.<\/p>\n<p><strong>Full-range fuses protect like two fuses, Back-up &amp; General-Purpose<\/strong>.<\/p>\n<div id=\"attachment_189\" style=\"width: 353px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2013\/06\/Full-Range-comparisions.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-189\" class=\" wp-image-189\" title=\"Full-Range fuse comparisons\" src=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2013\/06\/Full-Range-comparisions-300x250.jpg\" alt=\"Why Full-Range fuse is better than Back-up or GP\" width=\"343\" height=\"241\" \/><\/a><p id=\"caption-attachment-189\" class=\"wp-caption-text\">Why Full-Range fuse is better than Back-up or GP<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong><\/strong>\u00a0<strong>Full-range fuses protect the transformer by:<\/strong><\/p>\n<ol>\n<li>Meeting transformer inrush current points.<\/li>\n<li>Have a rated current sufficiently above the transformer rated current in order to allow for admissible overloads.<\/li>\n<li>Provide best possible protection during overload caused by winding short circuits.<\/li>\n<li>Discriminative currents over the complete interrupting range.<\/li>\n<\/ol>\n<p><strong>Increasing Switchgear safety<\/strong><\/p>\n<p>Switchgear safety can be increased by using Full-range fuses on the high voltage side of the transformer because other methods only protect against:<\/p>\n<ul>\n<li>Non coordinated fuses on the low voltage side of the transformer<\/li>\n<li>Short circuits in the transformer winding, ie transformer insulation failures<\/li>\n<li>Earth faults in the area around the transformer bushings<\/li>\n<\/ul>\n<p>The danger of this method is that admissible peak transformer currents are exceeded when the cables are loaded with their maximum, and transformer life-reducing excessive loads are only noticed after years.<\/p>\n<p>Also, back-up fuses used on the primary side of the transformer do not protect in an overload range situation where the insulation is in the process of failing. A slow steady current rise can occur when cracking insulation causes more and more windings to short-circuit. This increase in current occurs in the small overcurrent range of the transformer.<\/p>\n<p>Full-range fuses will effectively protect transformers against overloads caused either by the load or winding short-circuit. These fuses can be used as redundant protection so that even after failure of all other protective devices on the high and low voltage side, it offers a last means of safety before catastrophic damage occurs to your installation, buildings and environment.<\/p>\n<p>Consider Full-range fuses for applications with long cable runs and\/or high transformer impedance and Switchgear without 3-phase disconnecting device.<\/p>\n<p><strong>Reduced size and cost of switchgear by Full-range fuse<\/strong><\/p>\n<p>Back-up fuses need to be de-rated in transformer applications. For a 100A application a 125A back-up fuse would typically be used. With Full-range fuses, there is no de-rating of the fuse value, so a 100A is appropriate for a 100A application.<\/p>\n<p><strong>Protecting distribution transformers with full-range fuses<\/strong><\/p>\n<div id=\"attachment_190\" style=\"width: 310px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2013\/06\/Transformer-schmatic.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-190\" class=\"size-medium wp-image-190\" title=\"HV fuse location to protection transformer\" src=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2013\/06\/Transformer-schmatic-300x237.jpg\" alt=\"HV fuse should be located here to protect transformer\" width=\"300\" height=\"237\" srcset=\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2013\/06\/Transformer-schmatic-300x237.jpg 300w, https:\/\/blog.hilltech.com\/wp-content\/uploads\/2013\/06\/Transformer-schmatic.jpg 801w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-190\" class=\"wp-caption-text\">Schematic showing HV Full-range fuse location in order to protection transformer<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong><a title=\"Data sheet\" href=\"ftp:\/\/hilltech@hilltech.com\/www\/pdf\/fuses\/SIBA%20H00603_0.pdf\" target=\"_blank\" rel=\"noopener\">Ratings available<\/a>:<\/strong><\/p>\n<ul>\n<li>\u00a06\/12 kV:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 6.3 A \u2013 100 A<\/li>\n<li>10\/24 kV:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 (6.3 A) \u2013 50 A<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><strong>\u00a0Applications:\u00a0<\/strong><\/p>\n<ul>\n<li>Power centers<\/li>\n<li>Power transformer protection<\/li>\n<li>Load interrupters<\/li>\n<li>Feeder circuit protection<\/li>\n<li>Mine rectifiers<\/li>\n<\/ul>\n<p>For more questions on this article contact:<\/p>\n<p>Andrew Hill<br \/>\nHill Technical Sales<br \/>\n216 West Campus Drive<br \/>\nArlington Heights, IL 60004<br \/>\nTel: +1- 847-255-4400 ext 12 Fax: +1-847-255-0192<\/p>\n<p>You may also visit: <a href=\"http:\/\/www.hilltech.com\/\">http:\/\/www.hilltech.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>ARLINGTON HEIGHTS, ILLINOIS, USA, Monday, June 24, 2013: Hill Tech Sales, a leader in Components for Electrical Power Conversion today posted information on using true Full-range fuses to reduce the\u00a0size of switchgear. In the past, Full-range fuses used an inappropriate &hellip; <a href=\"https:\/\/blog.hilltech.com\/?p=186\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[165,180,178],"tags":[136,135,133,130,131,132,129,9,134],"class_list":["post-186","post","type-post","status-publish","format-standard","hentry","category-fuse","category-learning_center_hill_tech_sales","category-news_hill_tech","tag-1500vdc-fuse","tag-200ka-breaking-capacity","tag-ac-filter","tag-battery","tag-capacitor","tag-dc-link","tag-heater","tag-post-format-gallery","tag-urpv-ul-2579"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Reduce the size of switchgear designs and increase safety -<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.hilltech.com\/?p=186\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Reduce the size of switchgear designs and increase safety -\" \/>\n<meta property=\"og:description\" content=\"ARLINGTON HEIGHTS, ILLINOIS, USA, Monday, June 24, 2013: Hill Tech Sales, a leader in Components for Electrical Power Conversion today posted information on using true Full-range fuses to reduce the\u00a0size of switchgear. In the past, Full-range fuses used an inappropriate &hellip; Continue reading &rarr;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.hilltech.com\/?p=186\" \/>\n<meta property=\"og:site_name\" content=\"Hill Technical Sales Blog\" \/>\n<meta property=\"article:published_time\" content=\"2013-06-26T20:51:55+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-04-07T03:17:29+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/blog.hilltech.com\/wp-content\/uploads\/2013\/06\/Back-up-construction-300x225.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blog.hilltech.com\/?p=186#article\",\"isPartOf\":{\"@id\":\"https:\/\/blog.hilltech.com\/?p=186\"},\"author\":{\"name\":\"\",\"@id\":\"\"},\"headline\":\"Reduce the size of switchgear designs and increase safety\",\"datePublished\":\"2013-06-26T20:51:55+00:00\",\"dateModified\":\"2022-04-07T03:17:29+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blog.hilltech.com\/?p=186\"},\"wordCount\":911,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/blog.hilltech.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/blog.hilltech.com\/?p=186#primaryimage\"},\"thumbnailUrl\":\"http:\/\/blog.hilltech.com\/wp-content\/uploads\/2013\/06\/Back-up-construction-300x225.jpg\",\"keywords\":[\"1500VDC fuse\",\"200kA breaking capacity\",\"AC Filter\",\"battery\",\"capacitor\",\"DC Link\",\"heater\",\"post-format-gallery\",\"URPV UL 2579\"],\"articleSection\":[\"Fuse\",\"Learning Center\",\"News\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/blog.hilltech.com\/?p=186#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blog.hilltech.com\/?p=186\",\"url\":\"https:\/\/blog.hilltech.com\/?p=186\",\"name\":\"Reduce the size of switchgear designs and increase safety -\",\"isPartOf\":{\"@id\":\"https:\/\/blog.hilltech.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/blog.hilltech.com\/?p=186#primaryimage\"},\"image\":{\"@id\":\"https:\/\/blog.hilltech.com\/?p=186#primaryimage\"},\"thumbnailUrl\":\"http:\/\/blog.hilltech.com\/wp-content\/uploads\/2013\/06\/Back-up-construction-300x225.jpg\",\"datePublished\":\"2013-06-26T20:51:55+00:00\",\"dateModified\":\"2022-04-07T03:17:29+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/blog.hilltech.com\/?p=186#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blog.hilltech.com\/?p=186\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/blog.hilltech.com\/?p=186#primaryimage\",\"url\":\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2013\/06\/Back-up-construction.jpg\",\"contentUrl\":\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2013\/06\/Back-up-construction.jpg\",\"width\":\"1049\",\"height\":\"790\",\"caption\":\"Typical construction for Back-up & General Purpose fuses\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blog.hilltech.com\/?p=186#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/blog.hilltech.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Reduce the size of switchgear designs and increase safety\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blog.hilltech.com\/#website\",\"url\":\"https:\/\/blog.hilltech.com\/\",\"name\":\"Hill Technical Sales Blog\",\"description\":\"Your source for all your Power, Thermal Management and Imaging needs\",\"publisher\":{\"@id\":\"https:\/\/blog.hilltech.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blog.hilltech.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/blog.hilltech.com\/#organization\",\"name\":\"Hill Sales Corp\",\"alternateName\":\"Hill Technical Sales\",\"url\":\"https:\/\/blog.hilltech.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/blog.hilltech.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2016\/10\/Site-Icon-Hill-Tech-2.jpg\",\"contentUrl\":\"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2016\/10\/Site-Icon-Hill-Tech-2.jpg\",\"width\":512,\"height\":512,\"caption\":\"Hill Sales Corp\"},\"image\":{\"@id\":\"https:\/\/blog.hilltech.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.linkedin.com\/company\/hill-technical-sales-corp\",\"https:\/\/www.youtube.com\/@HillTechnicalSales\",\"https:\/\/www.instagram.com\/hill_tech_sales\/\"]},{\"@type\":\"Person\",\"@id\":\"\",\"url\":\"https:\/\/blog.hilltech.com\/?author=1\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Reduce the size of switchgear designs and increase safety -","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.hilltech.com\/?p=186","og_locale":"en_US","og_type":"article","og_title":"Reduce the size of switchgear designs and increase safety -","og_description":"ARLINGTON HEIGHTS, ILLINOIS, USA, Monday, June 24, 2013: Hill Tech Sales, a leader in Components for Electrical Power Conversion today posted information on using true Full-range fuses to reduce the\u00a0size of switchgear. In the past, Full-range fuses used an inappropriate &hellip; Continue reading &rarr;","og_url":"https:\/\/blog.hilltech.com\/?p=186","og_site_name":"Hill Technical Sales Blog","article_published_time":"2013-06-26T20:51:55+00:00","article_modified_time":"2022-04-07T03:17:29+00:00","og_image":[{"url":"http:\/\/blog.hilltech.com\/wp-content\/uploads\/2013\/06\/Back-up-construction-300x225.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Written by":"","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.hilltech.com\/?p=186#article","isPartOf":{"@id":"https:\/\/blog.hilltech.com\/?p=186"},"author":{"name":"","@id":""},"headline":"Reduce the size of switchgear designs and increase safety","datePublished":"2013-06-26T20:51:55+00:00","dateModified":"2022-04-07T03:17:29+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.hilltech.com\/?p=186"},"wordCount":911,"commentCount":0,"publisher":{"@id":"https:\/\/blog.hilltech.com\/#organization"},"image":{"@id":"https:\/\/blog.hilltech.com\/?p=186#primaryimage"},"thumbnailUrl":"http:\/\/blog.hilltech.com\/wp-content\/uploads\/2013\/06\/Back-up-construction-300x225.jpg","keywords":["1500VDC fuse","200kA breaking capacity","AC Filter","battery","capacitor","DC Link","heater","post-format-gallery","URPV UL 2579"],"articleSection":["Fuse","Learning Center","News"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/blog.hilltech.com\/?p=186#respond"]}]},{"@type":"WebPage","@id":"https:\/\/blog.hilltech.com\/?p=186","url":"https:\/\/blog.hilltech.com\/?p=186","name":"Reduce the size of switchgear designs and increase safety -","isPartOf":{"@id":"https:\/\/blog.hilltech.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.hilltech.com\/?p=186#primaryimage"},"image":{"@id":"https:\/\/blog.hilltech.com\/?p=186#primaryimage"},"thumbnailUrl":"http:\/\/blog.hilltech.com\/wp-content\/uploads\/2013\/06\/Back-up-construction-300x225.jpg","datePublished":"2013-06-26T20:51:55+00:00","dateModified":"2022-04-07T03:17:29+00:00","breadcrumb":{"@id":"https:\/\/blog.hilltech.com\/?p=186#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.hilltech.com\/?p=186"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.hilltech.com\/?p=186#primaryimage","url":"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2013\/06\/Back-up-construction.jpg","contentUrl":"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2013\/06\/Back-up-construction.jpg","width":"1049","height":"790","caption":"Typical construction for Back-up & General Purpose fuses"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.hilltech.com\/?p=186#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.hilltech.com\/"},{"@type":"ListItem","position":2,"name":"Reduce the size of switchgear designs and increase safety"}]},{"@type":"WebSite","@id":"https:\/\/blog.hilltech.com\/#website","url":"https:\/\/blog.hilltech.com\/","name":"Hill Technical Sales Blog","description":"Your source for all your Power, Thermal Management and Imaging needs","publisher":{"@id":"https:\/\/blog.hilltech.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.hilltech.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/blog.hilltech.com\/#organization","name":"Hill Sales Corp","alternateName":"Hill Technical Sales","url":"https:\/\/blog.hilltech.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.hilltech.com\/#\/schema\/logo\/image\/","url":"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2016\/10\/Site-Icon-Hill-Tech-2.jpg","contentUrl":"https:\/\/blog.hilltech.com\/wp-content\/uploads\/2016\/10\/Site-Icon-Hill-Tech-2.jpg","width":512,"height":512,"caption":"Hill Sales Corp"},"image":{"@id":"https:\/\/blog.hilltech.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/hill-technical-sales-corp","https:\/\/www.youtube.com\/@HillTechnicalSales","https:\/\/www.instagram.com\/hill_tech_sales\/"]},{"@type":"Person","@id":"","url":"https:\/\/blog.hilltech.com\/?author=1"}]}},"_links":{"self":[{"href":"https:\/\/blog.hilltech.com\/index.php?rest_route=\/wp\/v2\/posts\/186","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.hilltech.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.hilltech.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.hilltech.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.hilltech.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=186"}],"version-history":[{"count":18,"href":"https:\/\/blog.hilltech.com\/index.php?rest_route=\/wp\/v2\/posts\/186\/revisions"}],"predecessor-version":[{"id":450,"href":"https:\/\/blog.hilltech.com\/index.php?rest_route=\/wp\/v2\/posts\/186\/revisions\/450"}],"wp:attachment":[{"href":"https:\/\/blog.hilltech.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=186"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.hilltech.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=186"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.hilltech.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=186"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}