Hill Tech – Siba Fuse -Solar Power International Booth #419

Hill Tech personnel support Siba Fuse at Solar Power International Booth #419

 Hill Tech will be supporting Siba Fuse at the Solar Power International show in Anaheim CA, beginning Tuesday, October 27. This show has sold out the Exhibit Floor with 900 plus Companies Reserve 203,900 Sq. Ft. of space more than doubling show size from 2008. 

Siba will be showing its complete line of PV fuse for PV invertor protection and PV panel, junction box protection. 

If you are in the great lake region contact us to schedule design review or product training at the booth during the show. 

You my also contact Hill Tech at 847-255-4400 or visit www.hilltech.com

Posted in Events | Tagged , , , , | Leave a comment

Line scan cameras, UM2/UC2 now embed Pleora license for GigE

Our GigE line scan cameras from e2v now embed Pleora GigE technology providing the following benefits: 

  • Pleora license is free of charge for our customers.
  • e2v cameras are fully compatible with the GigEVision® and GenICam standards. Therefore, it can be operated from any other software/driver package that is compatible with such standards and in particular old e2v drivers
  • e2v drivers are not delivered any more but standard drivers are provided to you by our partners, which are constantly available to update to address any standard changes.

For more information contact: sales@hilltech.com

Posted in News, Product Announcements | Tagged , | Leave a comment

UV irradiator housing for easy conversion to UV curing

 –          FOR IMMEDIATE RELEASE –

Hill Tech introduces UV irradiator housing for easy conversion to UV curing

 Hill Tech introduces UV irradiator/ UV lamp housing for easy conversion of existing production lines from widths of 4 to 100 inches using traditional dryers to a UV drying/curing line.

 This standard line of lamp irradiator assemblies (LIA) which in addition to being an instant solution to reliable cooling of your UV lamp provide: 

  • Lamp mounting
  • A highly efficient method of focusing UV energy on to the curing surface.
  • Longer UV-lamp life.
  • More UV energy to the curing target improving your throughput.
  • Two focus versions.
  • Faster development time in implementing cooling for UV curing equipment.
  • No design or tooling investment required.
  • Reduced parts count.
  • An excellent option for UV retrofits system.
  • Improved quality and better UV cure results through consistent cooling.
  • Flexible lengths for almost any UV system: can be used for lamp arc lengths from 4 to 100 inches.  

There are easy steps list which example installation of these assemblies and other questions at: 

http://www.hilltech.com/faq/faq_uv.html#LIAfaqs

Posted in News, Product Announcements | Tagged , , , | Leave a comment

Pioneer Magnetics Repair Operation

So, What is going on?

 PMI’s products have been designed and are operating such that they stay out in the field longer than expected

 PMI’s products are being repaired by the third-party repair houses

 Some customers or end users (military and government) will repair the products themselves

 It may be too expensive to ship a product back to PMI so the end user will use a local repair company

 Some of the above/all of the above, etc.

I have had an opportunity to visit small, third party power supply repair houses as well as to talk with a large, power supply repair company. It is quite clear that the smaller companies do not necessarily use approved or new material. They get material by cannibalizing product as well as trying to “make do.” F.Y.I. – PMI does not normally sell its material to repair houses, which forces them to get material wherever they can. I have to assume that the larger companies do the same.

When it comes to upgrades, modifications or implementation of ECOS, etc, third party repair houses are unable to support this aspect of customer service.

At this point, PMI will repair and refurbish only its own product. But, it will certainly entertain replacing competitors’ old product that can no longer be repaired and/or no longer serviced by the competition.

There are scores of PMI competitors that are no longer in business and/or are no longer servicing their older products – especially the 5” X 8” X 11” power supplies – the same power supplies that PMI is still continuing to build.

Effective September 1st, PMI will:

 Officially launch its new Website.  See the link at http://www.hilltech.com/products/power_components/Power_Supplies.html#500-8000

Posted in News, Product Announcements | Tagged | Leave a comment

Advice on UL standards for LED sign applications

Do you know which UL standard the power supply needs to be in compliance with when it comes time to pick a power supply for your LED sign application? In this emerging and fast changing LED application market most people have a lot of questions about this such as:

• My LED sign application will be installed in an outdoor wet location. What should I look for to make sure the power supply can support this kind of application?

• UL48 used to be the standard which covered the electric signs industry. My application is an electric sign but is based on LED technology. Do I need to look for a power supply that meets the UL 48 standard?

• People have suggested that I get a power supply listed in the SAM? What is the SAM and where can I find the SAM?

To make the situation even more confusing many power supply vendors don’t know enough about UL regulations. Some power supply vendors only list the European standard, such as IP66, on their power supply specification. However; UL does not recognize the European IP specification. Using these power supplies requires the addition of a separate enclosure for the power supply to comply with UL’s wet location regulations and submission of the entire LED system to UL for approval.

Following are some explanations from our in-house specialist, Larry Brack, who works with several established LED sign companies and has assisted in the development of our entire LED power supply family.
“Your ultimate goal is to find a power supply listed in the Sign Components Manual (SAM). The SAM is published quarterly. If the power supply and all other components used are listed in the most recent SAM, the UL certification for your LED sign application is automatically granted. Imagine how much time and money you can save without having your application go through UL.”

“How can an LED power supply get listed in SAM? It needs to comply with UL 879, not UL 48. UL 879 is a fairly new standard designed to cover the safety concerns of the LED sign industry. The 8th edition of UL 879 just went into effect in late 2008.”

“Before the power supply can be reviewed for UL 879 it needs to approved against other UL standards guiding the power supply’s performance. The UL standards used for this evaluation will be different depending on the application. For example; an outdoor LED power supply must first be evaluated to UL 1310 Class II before submission for UL 879. In order to be approved for wet locations the power supply must also be evaluated to UL 50.” UL does not recognize TUV’s IP specifications to qualify for wet location approvals.”

“However; picking an LED power supply from the SAM is not the end of the story. When the SAM lists a component they describe the conditions of acceptability. I’ve seen unusual conditions of acceptability on LED power supplies that can severely limit their application in the field. Unless you allow for these “conditions of acceptability” you could incur increased costs and may not be able to get UL status for your end application.”

“The conditions of acceptability for our ANP-90, ANP-155, and ANP-240 LED power supply series are as simple and lenient as UL permits. They specify that Amperor’s power supplies only need to be installed at least 2 inches away from heat generating components; and, for wet locations, liquid tight conduit fittings need to be used at input and output wiring connections. Yes, they are as simple and straight forward as they read.”

If you need more help in picking the perfect power supply for your LED sign application come check out our website. You can contact us directly or our professional manufacturer’s representatives in your local area. We guarantee our revolutionary LED power supply family can save you both time and money in the implementation of your LED sign application.

Posted in Learning Center, News | Tagged | Leave a comment